Imagen

X02-04 - Purga Automática Serie X02 FRLs - Wilkerson

Dixon Distributor? 

Log in to view pricing, inventory, place orders & much more. If you want to create an account, please click the button to begin the registration process.

Atributos

Métrica de Presión de Operación Máxima
10.3 Bar
Presión de Operación Máxima
150 PSIG
Peso
1.13 lb
Break Quantity
1
Paquete Opcional/Cantidad por Caja
1
Rango de Temperatura
32°F to 125°F (0°C to 52°C)
Puerto
1/2"

Detalles

Description

Transparent bowl

Features

  • Transparent bowl
  • 5 oz. bowl
  • Fully automatic, float operated
  • Full 1/2" NPT drain inlet
  • Quick-disconnect clamp ring for easy bowl removal when servicing
  • No electrical connections
  • Easily installed

How It Works

As liquid contaminants collect in the bowl, they raise a closed-cell cellular float. When the liquid level reaches a given point, the float triggers a mechanism which pilots line pressure against a large area piston or diaphragm which snaps open the drain valve. The contaminants are discharged from the drain orifice at line pressure. As the liquid level falls, the pilot valve closes, line pressure against the piston/diaphragm returns to atmosphere and the drain valve snaps closed.

WARNING: This product contains lead, a chemical known to the State of California to cause cancer and birth defects or other reproductive harm.

Recursos